ion at rm o l Inf ra ne e G General Information ǁǁǁ ƌğljŵž ĐŽŵ 7

Size: px
Start display at page:

Download "ion at rm o l Inf ra ne e G General Information ǁǁǁ ƌğljŵž ĐŽŵ 7"

Transcription

1 General Information General Information 7

2 Research and Development Leadership Reliability Innovation Cutting-edge technology People 8

3 General Information The Company Huayi Group has a global presence; headquarters in China and subsidiaries in Europe. Huayi Compressor Co., Ltd. Huayi Compressor Co., Ltd. was founded in 1990, located in Jingdezhen, China, and is a worldwide leader of household compressor manufacturing. It specializes in the production of hermetic compressors with a complete range from 40W to 400W for refrigerators, water dispensers and dehumidifiers, among other household appliances. The core value of the company is Employee, Customer and Shareholder Satisfaction. Huayi Compressor Barcelona, S.L. Huayi Compressor Barcelona, S.L., subsidiary of Huayi Group, was founded in 1962 under the name of Unidad Hermética with the aim of producing hermetic compressors and cooling equipment. Today, the company belongs to Huayi Compressors Co. Ltd. Oriented to develop quality product supported by European production, with more than 100 million compressors produced under the Cubigel Compressors brand, the company mission has remained the same during its 51 years of experience developing compressors and satisfying the refrigeration market trends of Commercial Refrigeration. The compressors are designed to optimize energy consumption to reduce the effects of Global Warming, which are the goals of innovative R&D, focused on developing a wide range of products apt for the market requirements. General Information 9

4 10

5 General Information The Product Extended range of compressors The most complete range of hermetic compressors for every commercial application under the Cubigel Compressor brand. The offer includes more than 500 different models of compressors from ranges of 2.4 to 34cc, in most refrigerant gases, main voltages and types of applications. Condensing Units High quality hermetic condensing units with a wide range of options for most Commercial Refrigeration applications being also able to work under tropical temperature conditions. The range of condensing unit models covers both standard and customized versions. The green cooling ranges The advanced design of the Green Cooling ranges allows a remarkable efficiency improvement. These ranges comprise High Efficiency, Natural Refrigerants and the Variable Speed Compressors. This last one is crucial to reduce refrigeration energy consumption as the motor is electronically controlled. Compressors for mobile applications The best DC power supply compressors for mobile applications that are used in recreational vehicles, such as boats, caravans, cars that are equipped with refrigerators and freezers; and also in trucks or other transportation vehicles equipped with air conditioners in the sleeping cabins. 11

6 Family of Compressors and Condensing Units D range Features: Very compact design, Low weight, extra silent Range: 2.40 to 4.03 cc Refrigerants: R134a, R600a Applications: Water Coolers, Can Coolers, Bottle Coolers, Small Refrigerators and Freezers L range Features: The highest efficient range with propane (R290) & isobutene (R600a) Range: 4.00 to 9.9 cc Refrigerants: R134a, R404A, R600a, R290, R507, R22 Applications: Household Refrigerators, Bottle Coolers and Freezers, Can Coolers, Chest Freezers, Vending Machines, Ice Cream Freezers, Beer Dispensers, Ice Makers, Soft Drink Dispensers, Heat Pumps Systems L P P range Features: High Efficiency versions The highest efficient range with propane (R290) & isobutene (R600a) range with propane (R290) & isobutene (R600a) Range: cc Refrigerants: R134a, R404A, R600a, R290, R507, R22 Applications: Household Refrigerators, Bottle Coolers and Freezers, Can Coolers, Chest Freezers, Vending Machines, Ice Cream Freezers, Beer Dispensers, Ice Makers, Soft Drink Dispensers 12

7 General Information range Features: High reliability & efficiency. New design to work under heavy duty operation conditions Range: to cc Refrigerants: R134a, R404A, R290, R407C, R507, R22 Applications: Large Freezers (vertical and chest), Blast Freezers, Ice Makers, Vending Machines, Display Cabinets, Display Islands, Soft Drink Dispensers X S S range Features: Top capacity range, Optimized design to reduce vibration Range: to cc Refrigerants: R134a, R404A, R407C, R507, R22 Applications: Large Freezers (vertical and chest), Soft drinks dispensers, Blast Freezers, Air Dryers, Ice Makers, Air Conditioning, Vending Machines, Heat Pumps, Display, Cabinets and Islands CONDENSING UNITS Features: Complete range of Condensing Units from 2.4 to 34 cc High reliability & top-quality components Specific customized versions Designed to work under 43º C tropical conditions Refrigerants: R134a, R404A, R290, R407C, R507, R22 Applications: Suitable for all applications 13

8 The Green Cooling Ranges The most extended range of compressors for sustainable refrigeration in terms of energy consumption reduction. The advanced design of the Green Cooling Ranges allows efficiency improvement providing energy consumption reductions up to 45% compared to standard versions; consequently, lower CO 2 emissions to the atmosphere. The Green Cooling Ranges comprise High Efficiency, Natural Refrigerants and Variable Speed Compressors. The Green Cooling range gets to improve the compressor COP between 20% and 30% in comparison with standard ranges. High Efficiency Ranges The High Efficiency models reduce energy consumption of commercial refrigeration appliances between 10% and 30% with respect to standard ranges. Most High-Efficiency models are equipped with electric motors, designed with the "optional run capacitor" concept, that is, the compressor can work with or without a running capacitor (CSR/CSIR), offering the level of efficiency with the same compressor. Natural Refrigerants Natural refrigerants like propane (R290) and isobutene (R600a) are being gradually introduced in commercial appliances, not only due to the replacement of H-CFC s and HFC s refrigerants which have high impact on environment, but also because it is more efficient in terms of performance and applications' energy consumption. Refrigerant propane has no direct contribution to global warming and its energy consumption is between 10% to 15% lower than a similar application with R404A. The Cubigel Compressors R290 compressors offer a higher cooling capacity and COP allowing energy-saving consumption with smaller displacement. The major environmental benefits are obtained combining the use of the R290 with the design criteria of high efficiency ranges. These compressor models, in their more advanced version can save up to 50% of energy when compared with standard efficiency series of R404A thanks to its high-efficiency mechanics, its advanced motor winding design and the optional running capacitor concept. 14

9 General Information Variable Speed Compressors The Variable Speed Compressor offers the lowest energy consumption by means of electronically self-adjusting the compressor's speed to the appliance's cooling needs, while improving COP up to 50%. Using Smart Speed software with communication capabilities, this compressor automatically achieves the best efficiency for the appliance while dynamically adapting the compressor's speed to the needed cooling capacity. The major benefit can be obtained with a Variable Speed Compressor combined with the use of natural refrigerants, achieving a better performance with no contribution to global warming. Variable Speed Compressors Features: High Efficiency, Flexible Speed Drive Drop-in Configuration External Controlling V / 50-60Hz Models: GLT99FSN, NPT12FSC Refrigerant: R290, R134a 15

10 DC Compressors for mobile applications The Cubigel Compressors mobile cooling solutions for transportation vehicles are designed to operate from a 12-42V DC power supply. These compressors are designed for mobile DC applications in boats, trucks, private cars, medical appliances in ambulances, truck cabin air conditioners, among others. The GD30FDC model is the solution for users requiring comfort and reliability while traveling where a DC powered refrigerator is utilized. The GLT80TDC is the answer to the needs of users requiring comfort and reliability while traveling, either on holidays, at work or in any other circumstance where a DC powered air conditioner is utilized. The electronic driver from all Mobile Compressors include the Smart Speed programming option, which is a plug-in system for automatically self-adapting compressor speed to the current thermal load. The GD30FDC and GLT80TDC are designed to operate from a low voltage DC power supply to operate silently, efficiently and reliably even up to angles of tilt of 30º / 20º respectively, working with refrigerant R134a. DC Compressors Range Features: DC compressors for mobile applications, exceptionally silent GD30FDC VDE & UL approved Ready to work under heavy duty operating conditions 12-42V DC / 24-42V DC / 48-56V DC / V / 50-60Hz AC Models: GD30FDC, GLT80TDC. Refrigerant: R134a, R600A 16

11 Compressor Ranges Main Characteristics Compressor ranges - Main characteristics General Information Range D L P X S Displacement (cm 3 ) Cooling capacity (W) [*] LBP HMBP min max min max min max Weight (max) (kg) *All refrigerants / Measured at ASHRAE rating condition 50 Hz Identification Labels and Approvals R134a GL90TG V-50 Hz V-60 Hz PH Model Voltage Approvals Production Date Bar Code Refrigerant Approvals Directive compliance declarations Flammable gases 17

12 Compressor Nomenclature model GLY60RAa Indicates refrigerant. Not appearing in case of ranges for R22 G = R134a N = R290 M = R404A/R507 H = R600a G L Y 60 R A a Indicates compressor range (overall design). D = 2.4-4cm 3 P = 12-16cm 3 S = 18-34cm 3 L = cm 3 X = 16-23cm 3 Indicates energy efficiency level. Not appearing in case of R22 ranges and for standard efficiency. M = Medium Y = High Efficiency - Run Capacitor Optional RSIR/RSCR or CSIR/CSR T = Top Efficiency - Run Capacitor RSCR or CSR Indicates approximate compressor displacement under the following rule: D / L ranges 10 times the approx. displacement in cm 3 /rev (GL90TB -> approx 9 cm 3 /rev) P / X / S ranges The approx. displacement in cm 3 /rev (MX21TG -> approx 21 cm 3 /rev) Indicates the starting torque, application type and compressor cooling: A = LBP - LST - S G = LBP - LST - S (RSCR only) B = LBP - LST - OC L = LBP - HST - Fan (Current Relay) C = LBP - LST - FAN M = HMBP - LST/HST - S/FAN D = LBP - HST - S N = MBP - LST/HST - S/FAN E = LBP - HST - OC P = HMBP - LST - FAN F = LBP - HST -FAN R = HMBP - HST - FAN (CSR versions with Current Relay) T = HMBP - HST - FAN (CSR versions with Potential Relay) U = AC - LST/HST - FAN Y = VHBP - HST Fan Indicates the rated voltage: A = V 50Hz B = V 50Hz (old ranges) C = 100V 50/60Hz (old ranges) D = 115V 60Hz E = 115V 60Hz (old ranges) F = V 60Hz (old ranges) G = V 50Hz/ V 60Hz J = 100V 50/60Hz M = V 60Hz L/N = V 50Hz or V 50Hz V 60Hz (50ºC) R = V 60Hz (old ranges) T = V 50Hz U = V 60Hz 3 = 3 phase V 50/60Hz In case of old ranges R22, this character indicates refrigerant and constructive variations. Indicates a variant of the model that only affects the configuration of electrical components. Its meaning may vary from model to model. It does not appear on the compressor label but it is used for ordering, invoicing and Cubigel internal processes. Examples: 1. In high-efficiency compressors ( Y series, i.e.: GPY12LA or MLY80RD), the letters a or b may indicate the type of electrical connection corresponding to the electrical accessories supplied with the compressor. a = no use of running capacitor b = use of running capacitor c = static cooling and with starting capacitor d = fan cooling and with starting capacitor 2. In HMBP models of D range, R134a refrigerant (i.e.: GD30MB or GD40MB) it indicates the electrical accessories corresponding to the following situations: a = static cooling and without starting capacitor b = fan cooling and without starting capacitor 18

13 Voltage The standards consider the voltage variation of the network to be within +/- 6% of its rated value, nevertheless the Cubigel Compressors motors' design is able to work within -15% of the lowest rating and +10% of the highest rating. General Information Compressor Voltage Versions Voltage version Compressor rating Voltage operative range A or B C or J D or E G or F L or N M or R T U V 50 Hz 100 V 50/60 Hz 115 V 60 Hz / V 50/60 Hz V 50 Hz V 60 Hz V 60 Hz 400/440 V 50/60 Hz 3ph V 50 Hz V 50/60 Hz V 60 Hz / V 50/60 Hz V 50 Hz V 60 Hz V 60 Hz / V 50/60 Hz Applications Based on the characteristics of the system for which the compressor is intended, compressors are classified in different groups of application. Low Back Pressure (LBP) Compressors. Evaporating temperature range: -35 to -10ºC [-31ºF to +14ºF] (down to -40ºC [-40ºF] for refrigerant R404A). Rating condition: -25ºC [-13ºF] (CECOMAF) or -23.3ºC [-10ºF] (ASHRAE). High Back Pressure (HBP) Compressors. Evaporating temperature range: -15ºC to +10ºC [+5ºF to +50ºF]). Rating condition: +5ºC [+41ºF] (CECOMAF) or +7.2ºC [+45ºF] (ASHRAE). Medium Back Pressure (MBP) Compressors. Evaporating temperature range: -25ºC to 0ºC [-10 ºF to 32ºF] High Medium Back Pressure (HMBP) Compressors. Evaporating temperature range: -25 to +10 ºC [-13ºF to +50ºF]. Rating condition: +5ºC [+41ºF] (CECOMAF) or +7.2ºC [+45ºF] (ASHRAE). Very High Back Pressure (VHBP) Compressors. Evaporating temperature range 0ºC to +25ºC [+32 to +77ºF] with condensing temperature up to +75ºC [+167ºF]. The rating condition is defined by an internal Cubigel Compressors standard: Te = +10ºC [+50ºF]. 19

14 SOA - Safe Operating Area In order to grant the compressor reliability it is recommended that the point representing the operating conditions (suction and discharge pressures) falls within the shadowed area of the corresponding graph. SOA R134a LBP SOA R134a MBP SOA R134a HMBP SOA R134a HBP SOA R134a VHBP SOA R404A LBP 75 VHBP 60 LBP

15 SOA R404A HMBP SOA R404A HBP General Information 60 HMBP 60 HBP SOA R290 LBP SOA R290 HMBP SOA R22 HBP SOA R600a HMBP SOA R600a LBP SOA R22 HMBP 21

16 Types of Electrical Motors RSIR (Resistance Start-Induction Run) LST motor. No capacitors. Auxiliary winding is disconnected after start up. Standard energy efficiency. CSIR (Capacitor Start-Induction Run) HST motor. With starting capacitor. Auxiliary winding is disconnected after start up. Standard efficiency. RSCR (Resistance Start-Capacitor Run) LST motor. With running capacitor. Auxiliary winding remains connected after start up. Used for high efficiency in small capacity compressors (particularly in household refrigeration) CSR (Capacitor Start and Run) HST motor. Two capacitors (starting and running). Auxiliary winding remains connected after start up. Used for high efficiency in small compressors and for size reduced size motors in compressors with comparatively large displacements. Single phase motor classification Capacitor type With Running capacitor Motor type: CSR HST With starting capacitor Starting device: Current relay + NTC for L & P ranges Potential relay for P, X & S ranges LST Without starting capacitor Motor type: RSCR Starting device: PTC Without Running capacitor Motor type: CSIR Starting device: Current Relay Motor type: RSIR Starting device: Current Relay or PTC Type of starting device Type of torque Current relay RSIR engines, CSIR and CSR small (those with an NTC resistor in series with the starting capacitor to limit the current peak load). Potential relay (electromechanical). CSR high-power motors. LST Low Starting Torque Systems with capillary tube or balanced pressures at start up. HST High Starting Torque Systems with expansion valve or capillary tube, with unbalanced pressures at start up. PTC (Positive Temperature Coefficient), the resistance increases with the temperature. Device only with RSIR orrscr motors in the D, L and P ranges. NTC (Negative Temperature Coefficient), the resistance decreases with the temperature. Used in some CSR in order to reduce dimensions and components. 22

17 General Information Compressors Product Summary Refrigerants R290 R600a R134a R404A R507 R22 Application LBP HMBP VHBP Rated Voltages V 50HZ EU 100V 50/60HZ JAPAN V 60HZ USA - Latinamerica / V 50/60HZ 50Hz unstable net /230V 50/60HZ and 60Hz net V 50/60HZ 3PH More than 500 MODELS Motor RSIR RSCR CSIR CSR CSR + NTC 3PH DC Displacement Cooling Capacity 2.4 cm cm 3 35 kcal/h - 4,100 kcal/h (ASHARE) Starting Torque HST LST Efficiency STANDARD MEDIUM HIGH VARIABLE SPEED 23

18 Condensing Units Features, Benefits and Customized versions Cubigel Compressors offers a complete range of Condensing Units either standard or customized version, along with a wide variety of components to assemble customized condensing units. Features and Benefits Complete range from 2.4 to 34 cc High reliability & top-quality components High Efficiency version available Specific customized range Designed to work under 43ºC Suitable for all refrigerants & applications Condensing Units Main specific components Special power supply cable Special assembly supports (base plates) Dryer filters included (ceramic, molecular) Special pressure switches Non-assembled components Thermostat cables Special copper tubes (T connections) Sight glass Schrader valves Specific packaging Capillary tube Drain tray Main specific services Units UL approved on request Certified laboratory facilities at customer disposal Quick prototype building Quick quotation system Condensing Unit Versions Version "1" Basic equipment to be directly connected by soldering to the tubes of the condenser. Applicable to systems with a capillary expansion device. Version "2" Equipped with service valves in order to facilitate the connection and installation. Version "3" Equipped with service valves and liquid receiver. Applicable to systems with expansion valve. Version "3P" Version "3" additionally equipped with a hp/ lp pressure switch. Version "4" Version "1" additionally equipped with a Schrader valve on the refrigerant charging. 24

19 General Information Condensing Units Designation model CMS34TB3M2F C MS34TB3 M 2F C = Condensing Unit MS34TB = Compressor model = Version M = 38ºC N = 43ºC Max. Amb. Temp. 2F (Optional) = Two Fans - P (Optional in v.3) = hp/lp pressure switch Condensing Units Summary Refrigerants R290 R600a R134a R404A R507 R22 Application LBP HMBP VHBP Rated Voltages V 50HZ EU 100V 50/60HZ JAPAN V 60HZ USA - Latinamerica / V 50/60HZ 50Hz unstable net /230V 50/60HZ and 60Hz net V 50/60HZ 3PH More 500 than STANDARD MODELS Displacement Cooling Capacity 2.4 cm cm 3 35 kcal/h - 4,100 kcal/h (ASHARE) Standard Versions P 4 25

20 How to read this Catalogue Compressors Grouped by Refrigerant type Grouped by Application type Grouped by Application type Voltage Cooling capacity CECOMAF & ASHRAE Operative range of evaporating temp Indicates Green Cooling models Dimensional drawing reference Indicates New models R404A HMBP HBP REFRIGERATION CAPACITY COP in W/W 1 W = 0,864 kcal/h = 3,415 BTU/h Evaporating Temperature ºC Cecomaf (W) Ashrae cm 3 hp W COP 10 kcal/h COP Kg ML40TB /6 HMBP F V 50Hz ~1 CSIR R C-V Lc ML40TG /6 HMBP F / V 50/60Hz ~1 CSIR R C-V Lc ML45TB /5 HMBP F V 50Hz ~1 CSIR R C-V Lc ML45TG /5 HMBP F / V 50/60Hz ~1 CSIR R C-V Lc MODEL DISPLACEMENT POWER APPLICATION CPR COOLING VOLTAGE FREQUENCY MOTOR MLY60RAa /4 HMBP F V 50Hz ~1 CSIR R C-V Lc MLY60RAb /4 HMBP F V 50Hz ~1 CSR R C-V Lc ML60TB /4 HMBP F V 50Hz ~1 CSIR R C-V Lc ML60TG /4 HMBP F /230V 50/60Hz ~1 CSIR R C-V Lc MLY80RAa /8 HMBP F V 50Hz ~1 CSIR R C-V Ld MLY80RAb /8 HMBP F V 50Hz ~1 CSR R C-V Ld ML80TB /8 HMBP F V 50Hz ~1 CSIR R C-V Ld ML80TG /8 HMBP F / V 50/60Hz ~1 CSIR R C-V Ld MLY90RAa /8 HMBP F V 50Hz ~1 CSIR R C-V Ld MLY90RAb /8 HMBP F V 50Hz ~1 CSR R C-V Ld ML90TB /8 HMBP F V 50Hz ~1 CSIR R C-V Ld ML90TG /8 HMBP F /230V 50/60Hz ~1 CSIR R C-V Ld MP12RB /2 HMBP F V 50Hz ~1 CSR R C-V Pd MP12TG /2 HMBP F / V 50/60Hz ~1 CSR R C-V Pd MPT12RA (**) /8 HMBP F V 50Hz ~1 CSR R C-V Pd MP14RB /2 HMBP F V 50Hz ~1 CSR R C-V Pd MPT14RA (**) /2 HMBP F V 50Hz ~1 CSR R C-V Pd MX16TB /4 HMBP F V 50Hz ~1 CSR R C-V Xc MX18TB /8 HMBP F V 50Hz ~1 CSR R C-V Xd MX18TG /8 HMBP F / V 50/60Hz ~1 CSR R C-V Xd MX21TB HMBP F V 50Hz ~1 CSR R C-V Xd MX21TG HMBP F /230V 50/60Hz ~1 CSR R C-V Xd MS18T /8 HMBP F 400/440V 50/60Hz ~3 3PHASE R C-V Sc MS22TB HMBP F V 50Hz ~1 CSR R C-V Sc MS22T HMBP F 400/440V 50/60Hz ~3 3PHASE R C-V Sc MS26TB /8 HMBP F V 50Hz ~1 CSR R C-V Sd MS26TG /8 HMBP F /230V 50/60Hz ~1 CSR R C-V Sd MS26T /8 HMBP F 400/440V 50/60Hz ~3 3PHASE R C-V Sd MS34TB /8 HBP F V 50Hz ~1 CSR R C-V Sd MS34T /8 HMBP F 400/440V 50/60Hz ~3 3PHASE R C-V Sd MS34TG /8 HMBP F /230V 50/60Hz ~1 CSR R C-V Sd STARTING EXPANSION WEIGHT DESIGN 26

21 Condensing Units Grouped by Refrigerant type Grouped by Application type Grouped by Application type Voltage Cooling capacity CECOMAF & ASHRAE Operative range of evaporating temp General Information Dimensional drawing reference Indicates New models Indicates Green Cooling models R134a MODEL DISPLACEMENT POWER MAX. AMBIENCE TEMP. T = TROPICALIZED APPLICATION VOLTAGE FREQUENCY MOTOR EXPANSION REFRIGERATION CAPACITY W Wx 0.86 = kcal/h W x = BTU/h Evaporating Temperature ºC DIMENSIONS VERSION "3" TUBES SUCTION COMPRESSION WEIGHT 7.2 W x L x H cm 3 hp W W inp A 10 mm Inch Inch Kg CGD30MB_N /10 43 T HMBP V 50Hz ~1 CSIR C-V x300x200 1/4 1/ A CGD36MB_N /10 43 T HMBP V 50Hz ~1 CSIR C-V x300x200 1/4 1/ A CGD40MB_N /8 43 T HMBP V 50Hz ~1 CSIR C-V x300x200 1/4 1/ A CGL45PB_N /6 43 T HMBP V 50Hz ~1 RSIR C-V x425x220 3/8 1/ B CGL45TB_N /6 43 T HMBP V 50Hz ~1 CSIR C-V x425x220 3/8 1/ B CGL45TG_N /6 43 T HMBP / V 50/60Hz ~1 CSIR C-V x425x220 3/8 1/ B CGLY45RAa_N /6 43 T HMBP V 50Hz ~1 CSIR C-V x425x235 3/8 1/4 16 3B CGLY45RAb_N /6 43 T HMBP V 50Hz ~1 CSR C-V x425x235 3/8 1/4 16 3B CGL60PB_N /5 43 T HMBP V 50Hz ~1 RSIR C x425x235 3/8 1/4 17 3B CGL60TB_N /5 43 T HMBP V 50Hz ~1 CSIR C-V x425x235 3/8 1/4 17 3B CGL60TG_N /5 43 T HMBP / V 50/60Hz ~1 CSIR C-V x425x235 3/8 1/4 17 3B CGLY60RAa_N /5 43 T HMBP V 50Hz ~1 CSIR C-V x425x235 3/8 1/4 17 3B CGLY60RAb_N /5 43 T HMBP V 50Hz ~1 CSR C-V x425x235 3/8 1/4 17 3A CGL80PB_N /5 43 T HMBP V 50Hz ~1 RSIR C-V x425x235 3/8 1/4 17 3B CGL80TB_N /5 43 T HMBP V 50Hz ~1 CSIR C-V x425x235 3/8 1/4 17 3B CGL80TG_N /5 43 T HMBP / V 50/60Hz ~1 CSIR C-V x425x235 3/8 1/4 17 3B CGLY80RAa_N /5 43 T HMBP V 50Hz ~1 CSIR C-V x425x235 3/8 1/ B CGLY80RAb_N /5 43 T HMBP V 50Hz ~1 CSR C-V x425x235 3/8 1/ A CGL90PB_N /4 43 T HMBP V 50Hz ~1 RSIR C x425x235 3/8 1/ B CGL90TB_N /4 43 T HMBP V 50Hz ~1 CSIR C-V x425x235 3/8 1/ B CGL90TG_N /4 43 T HMBP / V 50/60Hz ~1 CSIR C-V x425x235 3/8 1/ B CGLY90RAa_N /4 43 T HMBP V 50Hz ~1 CSIR C-V x425x270 3/8 1/ B CGLY90RAb_N /4 43 T HMBP V 50Hz ~1 CSR C-V x425x270 3/8 1/ A CGP12PB_N /8 43 T HMBP V 50Hz ~1 RSIR C x425x270 3/8 1/4 20 3B CGP12TB_N /8 43 T HMBP V 50Hz ~1 CSIR C-V x425x270 3/8 1/4 20 3B CGP12TG_N /8 43 T HMBP / V 50/60Hz ~1 CSIR C-V x425x270 3/8 1/4 20 3B CGPY12RAa_N /8 43 T HMBP V 50Hz ~1 CSIR C-V x425x270 3/8 3/ B CGPY12RAb_N /8 43 T HMBP V 50Hz ~1 CSR C-V x425x270 3/8 3/ A CGP14PB_N /8 43 T HMBP V 50Hz ~1 RSIR C x425x270 3/8 1/ B CGP14TB_N /8 43 T HMBP V 50Hz ~1 CSIR C-V x425x270 3/8 1/ B CGP14TG_M / HMBP / V 50/60Hz ~1 CSIR C-V x425x270 3/8 1/ B CGPY14RAa_N /8 43 T HMBP V 50Hz ~1 CSIR C-V x510x300 3/8 3/ D CGPY14RAb_N /8 43 T HMBP V 50Hz ~1 CSR C-V x510x300 3/8 3/ E CGPY16RAa_N /8 43 T HMBP V 50Hz ~1 CSIR C-V x510x300 3/8 3/ D CGPY16RAb_N /8 43 T HMBP V 50Hz ~1 CSR C-V x510x300 3/8 3/ D DESIGN 27

Europe. Combine Strong Competitiveness and Reliability. Made in. lightcommercialrefrigeration.danfoss.com

Europe. Combine Strong Competitiveness and Reliability. Made in. lightcommercialrefrigeration.danfoss.com Danfoss Light Commercial Refrigeration Compressors Combine Strong Competitiveness and Reliability D, U, L, P, X, S Ranges Made in Europe lightcommercialrefrigeration.danfoss.com Compressor Ranges D Very

More information

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator Vicente Guilabert HUAYI COMPRESSOR BARCELONA, S.L The Company Huayi Compressor Barcelona, S.L.

More information

TECHNICAL NOTE. Use of R290 refrigerant recommendations. Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment

TECHNICAL NOTE. Use of R290 refrigerant recommendations. Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment TECHNICAL NOTE Use of R290 refrigerant recommendations Use of R290 refrigerant gas in hermetic compressors and commercial refrigeration equipment 1 1. HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today

More information

Low GWP alternative refrigerants to R404A

Low GWP alternative refrigerants to R404A HUAYI Statement: Low GWP alternative refrigerants to R404A Live the cooling experience The Company: HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today started out with Spanish and French capital in 1962,

More information

1. TF Hermetic Reciprocating Compressor

1. TF Hermetic Reciprocating Compressor 1. TF Hermetic Reciprocating Compressor The TF range of refrigeration compressors have cooling capacity from 37 to 1050W and coefficient of performance (COP) from 1.23 to 1.95 W/W. Our products have been

More information

0.4 In the preparation of this standard, assistance has been derived from the following standards:

0.4 In the preparation of this standard, assistance has been derived from the following standards: FOREWORD 0.1 Formal clauses will be added later. 0.2 The committee identified IS 10617(Pt 1), IS 10617(Pt 2) and IS 10617(Pt 3) for the first revision in the light of CFC free/hfc refrigerants and need

More information

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2007.3 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

CK C O M P R E S S O R

CK C O M P R E S S O R CJ62 6232 32CK CK C O M P R E S S O R TECHNICAL SPECIFICATION ; HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2011.8 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2005.10 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor Mechanical Information

More information

Electromechanical cold controls for refrigerators and freezers MAKING MODERN LIVING POSSIBLE. Type description

Electromechanical cold controls for refrigerators and freezers MAKING MODERN LIVING POSSIBLE. Type description MAKING MODERN LIVING POSSIBLE Type description Electromechanical cold controls for refrigerators and freezers REFRIGERATION & AIR CONDITIONG DIVISION Electromechanical cold controls for refrigerators and

More information

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications: Basic Facts About Hydrocarbons Q. What are hydrocarbons? Hydrocarbon refrigerants are environmentally friendly, non-toxic, non-ozone-depleting replacement for chlorofluorocarbons (CFCs), hydrochlorofluorocarbons

More information

Danfoss Scroll for Refrigeration MLM / MLZ

Danfoss Scroll for Refrigeration MLM / MLZ s Danfoss Scroll for Refrigeration MLM / MLZ 50-60 Hz - R404A - R507 - R134a - R22 - R407A - R407F http://danfoss.us.com/ Contents Features... 6 Scroll compression principle... 7 The scroll compression

More information

Electromechanical cold controls for refrigerators and freezers

Electromechanical cold controls for refrigerators and freezers Electromechanical cold controls for refrigerators and freezers danfoss.com Electromechanical cold controls for refrigerators and freezers Introduction Appliance Controls with its headquarters, and manufacturing

More information

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N (200-220~50Hz & 220-230V~60Hz) REFRITZ LTD 2016.08 1.Compressor Type Compressor model Approximate Power Rated voltage/frequency Refrigerant Application

More information

Reduce everything but reliability

Reduce everything but reliability Milk Cooling Tanks Reduce everything but reliability The dairy industry world has been through many changes with historically increasing operating costs and lower milk prices. Danfoss is commiteed to its

More information

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE Paolo VALERO Marek ZGLICZYNSKI Embraco Europe S.r.l. Via Buttigliera 6, 10020 Riva presso Chieri (To), Italy Fax: 0039-011-9437397

More information

This chapter is divided into four sections:

This chapter is divided into four sections: Danfoss Fitters notes Danfoss This chapter is divided into four sections: Page Mounting instructions............................................................................ 63 ondensing units in general......................................................................

More information

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice. ECO Energy efficient and environmentally friendly water and space heating SANYO Air Conditioners. The natural choice. CO 2 ECO Water Heater Energy efficient and environmentally friendly water and space

More information

COMPANY Presentation Focus on SANDEN Environmental Solutions

COMPANY Presentation Focus on SANDEN Environmental Solutions COMPANY Presentation Focus on SANDEN Environmental Solutions Liste de diffusion Top management General Manager Manager Manager de Tout le proximité monde SANDEN Group Worldwild specialist in heating and

More information

Introduction of Hanbell and

Introduction of Hanbell and Introduction of Hanbell and RC2 Series Screw Compressor Jude Chen April 2, 2007 Content 1.Hanbell Company Profile 2.Hanbell Machinery & Production 3.Basic Mechanism of Hanbell Screw Compressor 4.Hanbell

More information

Turbo air. Horizontal Bottle Coolers Model No. : TBC-24SD/SB TBC-36SD/SB. Commercial Refrigerator Service Manual TBC-95SD/SB TBC-65SD/SB TBC-80SD/SB

Turbo air. Horizontal Bottle Coolers Model No. : TBC-24SD/SB TBC-36SD/SB. Commercial Refrigerator Service Manual TBC-95SD/SB TBC-65SD/SB TBC-80SD/SB REFRIGERATOR MANUFACTURER Turbo air Commercial Refrigerator Service Manual Horizontal Bottle Coolers Model No. : TBC-24SD/SB TBC-36SD/SB TBC-50SD/SB TBC-65SD/SB TBC-80SD/SB TBC-95SD/SB TABLE OF CONTENTS

More information

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS COMMERCIAL REFRIGERATION RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS www.tecumseh.com Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) 1-HCFCs & HFCs Retrofit

More information

Embraco Position Paper: Light Commercial Refrigeration

Embraco Position Paper: Light Commercial Refrigeration Embraco Position Paper: Light Commercial Refrigeration Refrigerants Outlook 2018 www.embraco.com Introduction The global community, with Kigali Amendment to Montreal Protocol, made another important step

More information

This chapter is divided into four sections:

This chapter is divided into four sections: Contents This chapter is divided into four sections: Page Household compressors general information... 3 Household compressors how to handle... 21 Household compressors special requirements for R290 systems....

More information

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions Atmosphere Conference 2016 20/04/2016, Barcelona Hydrocarbons - Favouring Reduced Charge & Indirect Systems Traditional Rack Refrigeration

More information

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading

More information

Refrigerants & Cooling in renovation buildings

Refrigerants & Cooling in renovation buildings Refrigerants & Cooling in renovation buildings 01 Basics Refrigeration circuit. 1 Refrigeration Basics LP HP Mollier Diagram A-C Evaporation B-C Superheat C-D Compression D-E Desuperheat D-G Condensation

More information

3 GWP 290 DLE COMPRESSORS NLE/NLY COMPRESSORS SCE COMPRESSORS ENERGY-OPTIMIZED PROPANE COMPRESSORS

3 GWP 290 DLE COMPRESSORS NLE/NLY COMPRESSORS SCE COMPRESSORS ENERGY-OPTIMIZED PROPANE COMPRESSORS ENERGY-OPTIMIZED PROPANE COMPRESSORS R 290 DLE COMPRESSORS NLE/NLY COMPRESSORS SCE COMPRESSORS 3 GWP ACHIEVABLE WITH POWERFUL EFFICIENT LBP/MBP COMPRESSORS, DESIGNED FOR BOTTLE COOLERS, COMMERCIAL FREEZERS,

More information

MOBILE COOLING BUYING GUIDE EVERYTHING YOU NEED TO KNOW

MOBILE COOLING BUYING GUIDE EVERYTHING YOU NEED TO KNOW GUIDE BUYING GUIDE EVERYTHING YOU NEED TO KNOW Mobile living made easy. DEAR FREEDOM LOVER, There are millions of people around the world who use Dometic products. You all have one thing in common. You

More information

FLAMMABLE REFRIGERANTS UPDATE FOR HVAC&R EQUIPMENT IN NORTH AMERICA

FLAMMABLE REFRIGERANTS UPDATE FOR HVAC&R EQUIPMENT IN NORTH AMERICA FLAMMABLE REFRIGERANTS UPDATE FOR HVAC&R EQUIPMENT IN NORTH AMERICA April 2015 Barry Karnes, Principal Engineer UL LLC UL and the UL logo are trademarks of UL LLC 2015 1 Some History Pre 1990, most refrigerants

More information

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7

More information

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons. Danfoss components for hydrocarbon refrigeration Leapfrog Extensive to a portfolio long-term and solution expertise with for safe Danfoss and optimised wide product use of hydrocarbons portfolio for hydrocarbons

More information

This presentation is posted for public use. ACEEE does not endorse any product or service.

This presentation is posted for public use. ACEEE does not endorse any product or service. This presentation is posted for public use. ACEEE does not endorse any product or service. ACEEE accepts no responsibility for any facts or claims this presentation may contain. CO 2 Heat Pump Water Heater

More information

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Packaged Ammonia Chillers with Variable Frequency Drives powerpac Packaged Ammonia Chillers with Variable Frequency Drives powerpac John Ansbro Director Marketing Ammonia Refrigeration Background Frick ammonia compressor built in 1886. Installed at Gipps Brewery, Peoria,

More information

FX BLAST CHILLER ISO ISO 9001

FX BLAST CHILLER ISO ISO 9001 FX BLAST CHILLER ISO 14001 ISO 9001 Contents Environmental Management Policy 1 Disposal Requirements 1 Cabinet description 2 Controller Description Controller Operation 2 to 3 Alarms & Warnings 4 Parameter

More information

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit FSW Product guide CSECTION Driers and Sight Glasses For more information visit www.fsw.uk.com 47 Copper Spun Driers Suitable for HFC, CFC and HCFC. CODE MODEL SIZE CONNECTIONS C440 MSCD-5-3 5 Gram 3/16"

More information

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading

More information

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration Copeland Scroll (0.75-1.25HP) ZB*KA and ZF*KA for Refrigeration Copeland Scroll ZB*KA: Medium Temperature Copeland Scroll ZF*KA: Low Temperature 1 Contents Market Dynamics GWP Refrigerant Update Current

More information

Blue is better. Exclusive. compressor

Blue is better. Exclusive. compressor Exclusive compressor Jakarta 28-30 September 2017 MORE THAN 160 EMPLOYEES PRESENT IN 80 countries ITALY, CHINA, USA AND INDIA PRODUCTION CAPACITY OF 60000 COMPRESSORS PER YEAR AN ADVANTAGE THE SIZE OF

More information

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications: TECHNICAL DATA SHEET Features and uses of is a non-azeotropic blend of HFC with zero Ozone Depletion Potential et low Global Warming Potential (GWP), formulated to meet the requirements of the F-Gas Regulation

More information

Natural refrigerant trends in EU, Japan & North America

Natural refrigerant trends in EU, Japan & North America Natural refrigerant trends in EU, Japan & North America Paris, 17 July 2014 Klara Skacanova, senior analyst shecco Agenda Policy action & market for natural refrigerants: EU Japan North America Europe:

More information

Optyma Slim Pack Condensing Units

Optyma Slim Pack Condensing Units Optyma Slim Pack Condensing Units Main Product Features Outdoor Applications Weatherproof Housing IP54 Robust and resistant to corrosion Compact design Crankcase Heater Service Shut Off Valves Micro Channel

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

Elecstar Professioinal Refrigeration

Elecstar Professioinal Refrigeration Elecstar Professioinal Refrigeration version 1211A (1st revised in NOV) LECSTAR 1 INTRODUCTION ABOUT US We are neither manufacturer nor trader! We are a sourcing company help customer find the balance

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011 Natural Refrigerants: Future-proof Solutions for Today eurammon End-Users Day 2011 New Chillers for air-conditioning applications and Heat Pumps by Ir. Danny Heuvelmans, Sales Director, GEA Grasso Introduction

More information

For more information on the MARR program or any questions on the product list, please refer to or contact MARR at

For more information on the MARR program or any questions on the product list, please refer to   or contact MARR at Major Appliance Recycling Roundtable Updated Major Appliance Recycling Roundtable - and s Background: The following document provides a detailed list of products and relevant definitions captured by the

More information

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG. AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG. Page1 CONTENT: 1. Product Description 2. Product Specifications 3. Operating Procedure 4. Observation Table 5. Calculations 6. Result Page2

More information

A Comparison Between Refrigerants Used In Air Conditioning

A Comparison Between Refrigerants Used In Air Conditioning A Comparison Between Refrigerants Used In Air Conditioning Derya Özkan, Özden Agra and Özlem Çetin University of Yildiz Technical University, Turkey Corresponding email: tumer@yildiz.edu.tr SUMMARY It

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for WILLIAMS

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for WILLIAMS GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for WILLIAMS WILLIAMS heating elements/thermostats/probes/electronics heating elements heating elements

More information

Refrigerant Dryers DRY with PDP Indicator

Refrigerant Dryers DRY with PDP Indicator Refrigerant Dryers DRY with PDP Indicator Refrigerant dryers range From 333 lt./min up to 21.000 lt./min PDP: 5 C at reference conditions Whole range with the PDP indicator Max. working pressure: 16 bar

More information

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America. Over

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America. Over Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America Go Beyond Cool With Danfoss, build sustainable and efficient walk-in coolers & freezers. Our wide range of products and market leading

More information

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency. Energy saving refrigeration dryers 10-1000 SCFM Purifying your compressed air, increasing your efficiency. Refrigeration dryers with Energy Saving Pulse Technology and Thermal Mass With the introduction

More information

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-

More information

Industrial cooling systems LT

Industrial cooling systems LT Industrial cooling systems LT 01 Industrial cooling and heating. Partner of the industry for over 40 years. Since 1971 DELTATHERM has belonged to Hirmer GmbH, a family business with its headquarters in

More information

Environmentally friendly refrigeration systems for industrial use

Environmentally friendly refrigeration systems for industrial use compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future GENERAL INFORMATION compindustri More than 10 years of development of refrigeration

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

AK 2 Series Compressor

AK 2 Series Compressor AK 2 Series Compressor Reference Guide Commercial Refrigeration Applications www.tecumseh.com AK 2 SERIES COMPRESSOR AK 2 Compressor Reference Guide ECO-FRIENDLY AK 2 is optimized for use with eco-friendly

More information

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a ISSN (e): 0 00 Vol, 0 Issue, 8 August 0 International Journal of Computational Engineering Research (IJCER) Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants

More information

HFO-1234yf Performance in a Beverage Cooler

HFO-1234yf Performance in a Beverage Cooler 2422 Page 1 HFO-1234yf Performance in a Beverage Cooler Barbara MINOR 1 *, Carlos MONTOYA 2, Francisco Sandoval KASA 3 1 DuPont Fluoroproducts, Wilmington, DE, USA Phone: 302-999-2802, E-mail: barbara.h.minor@usa.dupont.com

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of

More information

world natural refrigerants trends market availability, technology trends & the impact of policy

world natural refrigerants trends market availability, technology trends & the impact of policy world natural refrigerants trends market availability, technology trends & the impact of policy San Francisco, June 18, 2014 Nina Masson, Deputy Managing Director shecco natural refrigerants world trends

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications. TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there

More information

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.) : new refrigerant replacement for R-22 with low Global Warming Potential (GWP). Performance comparison with six existing refrigerants. CARRIED OUT BY DIRA S.L. (Desenvolupament, Investigació i Recerca

More information

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. INSTRUCTION MANUAL Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. 1 CF-300K Dear customers, Thank you for purchasing our product.

More information

Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima

Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima page 1 Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima No-idle auxiliary battery operated air con PICCOLO SPLITTER Model PS3000 MY2012

More information

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63 64 Head Office 01543 437 010 Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator

More information

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer: Information Sheet GEN 5 Refrigerant Quantity General Guidance 1. How much refrigerant is in the system? If you have established that you are using an HFC refrigerant in a refrigeration system, the next

More information

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube ISSN: 2347-3215 Volume 1 Number 4 (2013) pp. 46-54 www.ijcrar.com Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube Richa Soni 1*, P.K.Jhinge

More information

2013 ASHRAE. Standards & Guidelines CD. Contents

2013 ASHRAE. Standards & Guidelines CD. Contents 2013 ASHRAE Standards & Guidelines CD Contents ANSI/ARI/ASHRAE ISO Standard 13256-1:1998 (RA 2012) Water-source heat pumps testing and rating for performance Part 1: Water-to-air and brine-to-air heat

More information

PROFESSIONAL REFRIGERATION

PROFESSIONAL REFRIGERATION PROFESSIONAL REFRIGERATION 2015/2016 PERFORMING EXCELLENCE Offering the best performance for modern catering: Smeg Foodservice is the Smeg division dedicated to the needs of the professional catering sector.

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

Robust Construction, Technology, Quality, Reliability and Repeatability for extreme Tropic Conditions

Robust Construction, Technology, Quality, Reliability and Repeatability for extreme Tropic Conditions Robust Construction, Technology, Quality, Reliability and Repeatability for extreme Tropic Conditions 12 V - 24 V DC operating voltage featuring shut-off at low voltage Dual Mode - Can work as Freezer

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

REFRIGERATOR RB195BSSW RB195BSSB RB195BSVQ RB195BSBB RB215BSSW RB215BSSB RB215BSVQ RB215BSBB. Reversible Door Auto Ice-Maker Fridge Wire Box

REFRIGERATOR RB195BSSW RB195BSSB RB195BSVQ RB195BSBB RB215BSSW RB215BSSB RB215BSVQ RB215BSBB. Reversible Door Auto Ice-Maker Fridge Wire Box REFRIGERATOR RB195BSSW RB195BSSB RB195BSVQ RB195BSBB RB215BSSW RB215BSSB RB215BSVQ RB215BSBB REFRIGERATOR PRODUCT FEATURE Reversible Door Auto Ice-Maker Fridge Wire Box WARNING IMPORTANT SAFETY NOTICE

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for AFINOX

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for AFINOX GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for AFINOX AFINOX heating elements/switches and momentary switches heating elements heating elements

More information

The specifications in this document are subject to change without notice. DFD - DH Series. Desiccant Flexible Dryer & Drying Hopper Systems

The specifications in this document are subject to change without notice. DFD - DH Series. Desiccant Flexible Dryer & Drying Hopper Systems The specifications in this document are subject to change without notice. DFD - Series Desiccant Flexible Dryer & Drying Hopper Systems Desiccant Flexible Dryer Introduction Drying of plastics raw materials

More information

Product Catalog VALVES

Product Catalog VALVES SUIKA CLIMATE Product Catalog VALVES CONTACT WEB Info@suikaclimate.com ADDRESS Fremont, CA, 94555 TELEPHONE +1 (800) 625 0589 +1 (510) 859 8003 Suika Climate Toeflex ABOUT US Suika Climate (US), Toeflex

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL OIL-INJECTED ROTARY SCREW COMPRESSORS THE NEW G-SERIES The latest-generation G-series comes with Atlas Copco s powerful rotary screw element and an advanced electronic controller on the to go above and

More information

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN E. Hihara, Professor, Institute of Environmental Studies, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan The conventional refrigerant

More information

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000

More information

Global Solutions for Ammonia Industrial Refrigeration

Global Solutions for Ammonia Industrial Refrigeration Global Solutions for Ammonia Industrial Refrigeration MAYEKAWA s lineups and results of Natural Refrigerants Atmosphere 2009 October19th 2009 Mayekawa Mfg. Co., Ltd. Kuniaki Kawamura 1 Founded: 1924 Location:

More information

Maneurop reciprocating compressors MT / MTZ

Maneurop reciprocating compressors MT / MTZ Maneurop reciprocating compressors MT / MTZ 50-60 Hz - Group 2: R22 - R417 - R407/C/F - R134a - R404 / R507 - R448 / R449 - R452 http://danfoss.us.com/ Contents Maneurop reciprocating compressors...4

More information

APPLICATION OF HEAT PUMP SYSTEM FOR ECO-FRIENDLY VEHICLES

APPLICATION OF HEAT PUMP SYSTEM FOR ECO-FRIENDLY VEHICLES Numbers of Abstract/Session (given by NOC) - 1 - APPLICATION OF HEAT PUMP SYSTEM FOR ECO-FRIENDLY VEHICLES Toshihisa Kondo, Acting Manager, Future Systems Designing Group, Automotive Thermal Systems Department,

More information

Doc. Code Emission Revision Date Page /36

Doc. Code Emission Revision Date Page /36 09001 2009-04 01 2009-06 1/36 This manual may not be reproduced in whole or part without prior permission from EMBRACO. 09001 2009-04 01 2009-06 2/36 Index Page 1. Introduction... 03 2. Compressor Ranges...

More information

SEMI-HERMETIC SCREW COMPRESSORS

SEMI-HERMETIC SCREW COMPRESSORS SEMI-HERMETIC SCREW COMPRESSORS 50 Hz // SP-00-5 EN HS.53 // HS.64 // HS.74 // HS.5 // HS.95 WITH IQ MODULE BIGGER MODELS BITZER Innovation Targets Semi-hermetic screw compressors Products for refrigerants

More information

Refrigerant Glide and Effect on Performances Declaration

Refrigerant Glide and Effect on Performances Declaration Refrigerant Glide and Effect on Performances Declaration Scope and Purpose As a consequence of the EU regulation 517/2014 (F-gas), the future synthetic refrigerants with a low global warming potential

More information

Maneurop reciprocating compressors MT / MTZ

Maneurop reciprocating compressors MT / MTZ Maneurop reciprocating compressors MT / MTZ 50-60 Hz - R22 - R417A - R407A/C/F - R134a - R404A / R507 http://danfoss.us.com/ Contents Maneurop reciprocating compressors... 5 Compressor model designation...

More information

Mechanical Heat Pump R515

Mechanical Heat Pump R515 P.A.Hilton Ltd Mechanical Heat Pump R515 Above: R515 shown fitted with standard wattmeter Stabilises in minutes allowing many tests to be conducted in a typical laboratory period. Allows a complete refrigerant

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

UPRIGHT REFRIGERATORS FOR RV AND MARINE APPLICATIONS INSPIRED BY COMFORT.

UPRIGHT REFRIGERATORS FOR RV AND MARINE APPLICATIONS INSPIRED BY COMFORT. UPRIGHT REFRIGERATORS FOR RV AND MARINE APPLICATIONS INSPIRED BY COMFORT www.dometic.co.nz 2 FEATURES OF DOMETIC 3 WAY REFRIGERATORS ABSORPTION REFRIGERATION FOR 12 VOLTS, 240 VOLTS AND GAS Famous 3 way